References
 
unsere Kunden...

Happy Customers

Happy customers are our best reference, and we have a lot. Experience counts, OCHSNER has built over 85.000 Heat Pumps so far.

OCHSNER offers a complete range of Heat Pumps for ground, water or air as heat source and for capacities from 2 kW to over 1.000 kW.
 

References

Family house :
Heat Pump:
Capacity (S0/W35):
Year of manufacture:
Heat source:
Heating size:
Heating system:
Hot water production:


System Partner:

 

Grude, Appenheim (D)
OCHSNER Golf GMSW 15
11 kW
2005
ground-brine, 3 tubes
210 m²
underfloor heating
OCHSNER Europa 312 (outgoing air from controlled dwelling ventilation)
ESR-Bolender, Langenlohnsheim


Family house :
Heat Pump:
Capacity (E0/W35):
Year of manufacture:
Heat source:

Heating size:
Heating system:
Hot water production:
Annual heating costs:
System Partner:

 

Nemec, Föderlach (A)
OCHSNER Golf GMDW 9
8,9 kW
2003
ground direct expansion, 3 circles
165 m²
underfloor heating
with heating heat pump
approx. 700 € (incl. hot water)
Trubka GmbH, Latschach


Family house:
Heat Pump:
Capacity (E0/W35):
Year of manufacture:
Heat source:

Heating size:
Heating system:
Hot water production:
Annual heating costs:
System Partner:

Liebelt, Grolsheim (D)
OCHSNER Golf GMDW 9
8,9 kW
2005
ground direct expansion, 5 circles
200 m²
underfloor heating
OCHSNER Europa 312
n/a, due to first season
ESR-Bolender, Langenlohnsheim


Family House
"Bliem's Genuss.Reich"

Heat Pump:
Capacity (S0/W35):
Year of manufacture:
Heat source:
Heating size:
Heating system:

Hot water production:


Annual heating costs:

Bliem, Thalgau (A)


OCHSNER OSWP 31
23,15 kW
1989
ground-brine, 3 tubes
approx.. 500 m²
underfloor heating/low temperature radiators
OCHSNER Mini Gastronom
(high demand for domestic hot water)
approx. 2.300 € (incl. hot water.)


Family House
Heat Pump:
Capacity (E0/W35):
Year of manufacture:
Heat source:
Heating size:
Heating system:
Hot water production:


System Partner:

Herzmann, Münchwald (D)
OCHSNER Golf GMDW 9
8,9 kW
2005
ground direct expansion -285m²
200 m²
underfloor heating
OCHSNER Europa 312 (outgoing air from controlled dwelling ventilation)
ESR-Bolender, Langenlohnsheim


Apartment building:
Heat Pump:
Capacity (S0/W35):
Year of manufacture:
Heat source:
Heating size:
Heating system:
Hot water production:
Annual heating costs:

 

Dr. Rinner , Gmunden (A)
OCHSNER OSWP 56
39,9 kW
1998
ground-brine, 5 tubes
approx. 800 m²
underfloor heating
OCHSNER Europa 302EW
approx. 3000 € (incl. hot water)


Family house :
Heat Pump:
Capacity (L2/W35):
Year of manufacture:
Heat source:
Heating size:
Heating system:
Hot water production:
Annual heating costs:
System Partner:

Heinemann, Helsa (D)
OCHSNER Golf GMLW 9
8,5 kW
2003
air - split version
140 m²
underfloor heating
OCHSNER Europa 312
approx. 300 € (without hot water)
Schäfer Michael, Helsa


Apartment building:
(Heating renovation)
Heat Pump:
Capacity (W10/W50):
Year of manufacture:
Heat source:
Heating size:
Heating system:
Hot water production:
System Partner:

 

Buchschachermair,
Scharnstein
(A)
OCHSNER Golf GMWW 21
18 kW
2005
ground water
190 m²
low temperature radiators
with heating heat pump
BM, Scharnstein


apartment building - operationally used:
Heat Pump:
capacity (L2/W35):
Year of manufacture:
Heat source:
Heating size:
Heating system:
Hot water production:
Annual power consumption:
Annual heating costs:
System Partner:


Reusse, Helsa (D)
OCHSNER Golf GMLW 25
22,4 kW
2005 - heating renovation
air - split version
400 m²
underfloor heating + radiators
OCHSNER Europa 312

8.198 kWh
approx. 1.020 €
Schäfer Michael, Helsa


Family house :
Heat Pump:
Capacity (E0/W35):
Year of manufacture:
Heat source:

Heating size:
Heating system:
Hot water production:
Annual heating costs:
System Partner:

Gruber, Ledenitzen (A)
OCHSNER Golf GMDW 9
8,9 kW
2003
ground direct expansion,
5 circles
204 m²
underfloor heating
with heating heat pump
approx. 500 € (incl. hot water)
Trubka GmbH, Latschach


Family house :
Heat Pump:
Capacity (L2/W35):
Year of manufacture:
Heat source:
Heating size:
Heating system:
Hot water production:
Annual heating costs:
System Partner:

Kreer, Weinsheim (D)
OCHSNER Golf GMLW 14
12,7 kW
2004
air - split version
220 m²
underfloor heating
OCHSNER Europa 302
n/a
ESR-Bolender, Langenlohnsheim


Family house :
Heat Pump:
Capacity (S0/W35):
Year of manufacture:
Heat source:
Heating size:
Heating system:
Hot water production :
Annual heating costs:
System Partner:

Schinkinger, Kollerschlag A
OCHSNER Golf GMSW 21
15,0 kW
2005
ground-brine, 2 tubes à 100 m
approx. 270 m²
underfloor heating
with heating heat pump
n/a, due to first season
Lauss, Haslach


Family house :
Heat Pump:
Capacity (S0/W35):
Year of manufacture:
Heat source:
Heating size:
Heating system:
Hot water production:
Annual heating costsr:
System Partner:

Gaisberger, Bad Aussee (A)
OCHSNER Golf GMSW15
11,0 kW
2001
ground-brine., 4 circles
140 m²
underfloor heating
by heating heat pump
approx. 350 € (incl. hot water)
Grieshofer, Grundlsee


Family house:
Heat Pump:
Capacity (E0/W35):
Year of manufacture:
Heat source:

Heating size:
Heating system:
Hot water production:
Annual heating costs:
System Partner:

Maurer-Nuck, Ledenitzen (A)
OCHSNER Golf GMDW 14
13,5 kW
2005
ground direct expansion,
7 circle
160 m²
underfloor heating
per heating heat pump
n/a, due to first season
Trubka GmbH, Latschach


Family house:
Heat Pump:
Capacity (E0/W35):
Heat source:
Heating size:
Heating system:
Annual heating requirement:
Annual power consumption:
COP HP:
Annual heating costs:

Hofbauer, Gramastetten (A)
OCHSNER Golf GMDW 12
11 kW
ground direct expansion
200 m²
underfloor heating

19.904,7 kWh

4.629 kWh
4,3
470,96 €


Family house:
Heat Pump:
Capacity (S0/W35):
Year of manufacture:

Heat source:

Heating size:
Heating system:

Hot water production:
Annual heating costs:

System Partner:

Rode, Helsa (D)
OCHSNER Golf GMSW 18
13,5 kW
2005 - as replacement for old heat pump
ground-brine, 6+1 circles
(1 circle on the roof)
249 m²
underfloor heating/ low temperature radiators
by heating heat pump
approx. 720 € (with old heat pump)

Schäfer Michael, Helsa


Family house :
Heat Pump:
Capacity (S0/W35):
Heat source:
Heating size:
Heating system:
Annual heating requirement:
Annual power consumption:
COP HP:
Annual heating costs:

Tauschek, Peuerbach (A)
OCHSNER Golf GMSW 33
24,2 kW
brine, 4 tubes à 100 m
550 m² + indoor pool
underfloor heating

38.574,9 kWh

9.891 kWh
3,9
1.006,33 €




Family house :
Heat Pump:
Capacity (S0/W35):
Year of manufacture:
Heat source:
Heating size:
Heating system:

Hot water production:
Annual heating costs:
System Partner:

Kopeinig, Köstenberg (A)
OCHSNER Golf GMSW 21
15,0 kW
2005
ground-brine, 2 tubes à 85m
180 m²
underfloor heating/ low temperature radiators
mit Heizungs-Wärmepumpe
n/a due to first season
Trubka GmbH, Latschach


Production hall:

Heat Pump:
Capacity (L2/W50):
Year of manufacture:
Heat source:
Heating size:
Heating system:

System Partner:

Pall Corporation,
Bad Kreuznach (D)
OCHSNER Golf GMLW 25
21,4 kW
2004
air - split version
approx. 200 m²
Deckenradiatoren (50° flow temperature)
ESR-Bolender, Langenlohnsheim


Schoolhouse :
Heat Pump:
Capacity (S0/W35):
Heat source:
Hot water production:
Hydraulic system:
Heating system:

Commune Neveklov
OCHSNER OSWP 270
513 kW
brine, 64 tubes
by heating heat pump
with buffer tank
radiator heating